Mantis Bugtracker

Простой вид комментарии ] расширенный вид ] история ] печать ]
Номер Категория Серьезность Воспроизводимость Создан Изменен
0000433 [obex-data-server] General большая иногда 2010-04-18 11:24 2010-04-19 00:07
Инициатор crevette Видимость общая  
Ответственный
Приоритет обычный Решение открыт  
Состояние новый   Версия продукта 0.4.5
Суть 0000433: obex-data-server crashed with SIGSEGV in g_main_context_dispatch() after transfer
Подробности There is a crasher that make o-d-s crash after a transfer, the stacktrace is not complete because some glib symbols were missing, I'm waiting a better one from reporters.

.
Thread 1 (process 1421):
#0 obex_io_callback (io_channel=0x938c348, cond=<value optimized out>,
    data=0x938e978) at src/ods-session.c:193
    session = (OdsSession *) 0x0
    error = (GError *) 0x0
    ret = <value optimized out>
    __FUNCTION__ = "obex_io_callback"
#1 0x00299e6b in ?? () from /lib/libglib-2.0.so.0
No symbol table info available.
#2 0x002555e5 in g_main_context_dispatch () from /lib/libglib-2.0.so.0
No symbol table info available.
0000003 0x002592d8 in ?? () from /lib/libglib-2.0.so.0
No symbol table info available.
0000004 0x00259817 in g_main_loop_run () from /lib/libglib-2.0.so.0
No symbol table info available.
0000005 0x08051b5d in main (argc=2, argv=0xbf91e594) at src/ods-main.c:195
    session_connection = <value optimized out>
    error = (GError *) 0x0
    context = <value optimized out>
    sa = {__sigaction_handler = {sa_handler = 0x80515f0 <sig_term>,
    sa_sigaction = 0x80515f0 <sig_term>}, sa_mask = {__val = {
      0 <repeats 32 times>}}, sa_flags = 0, sa_restorer = 0}
    no_daemon = 1
    system_bus = 0
    show_version = 0
    log = 0
    debug = 0
    options = {{long_name = 0x8064775 "no-daemon", short_name = 110 'n',
    flags = 0, arg = G_OPTION_ARG_NONE, arg_data = 0xbf91e4c8,
    description = 0x806477f "Do not daemonize", arg_description = 0x0}, {
    long_name = 0x8064790 "system-bus", short_name = 115 's', flags = 0,
    arg = G_OPTION_ARG_NONE, arg_data = 0xbf91e4c4,
    description = 0x8064888 "Use system bus instead of the default session bus", arg_description = 0x0}, {long_name = 0x80647b2 "log", short_name = 108 'l',
    flags = 0, arg = G_OPTION_ARG_NONE, arg_data = 0xbf91e4bc,
    description = 0x806479b "Log all messages to syslog",
    arg_description = 0x0}, {long_name = 0x80647b6 "debug",
    short_name = 100 'd', flags = 0, arg = G_OPTION_ARG_NONE,
    arg_data = 0xbf91e4b8,
    description = 0x80647bc "Enable debugging messages",
    arg_description = 0x0}, {long_name = 0x80647d6 "version",
    short_name = 118 'v', flags = 0, arg = G_OPTION_ARG_NONE,
    arg_data = 0xbf91e4c0,
    description = 0x80648bc "Show version of obex-data-server and exit immediately", arg_description = 0x0}, {long_name = 0x0, short_name = 0 '\0',
    flags = 0, arg = G_OPTION_ARG_NONE, arg_data = 0x0, description = 0x0,
    arg_description = 0x0}}
Дополнительные сведения Downstream bug:
https://bugs.launchpad.net/ubuntu/+source/obex-data-server/+bug/559876 [^]
Tэги Нет прикрепленных тэгов.
Вложенные файлы

- Связи

-  Комментарии
(0001242)
skirsdeda (администратор)
2010-04-19 00:07

This is probably fixed in svn already. If someone can test with svn version, it would be great but there is high probability that it's already fixed. I just need to do a new release (probably in the beginning of may).

- история
Дата изменения Пользователь Поле Изменение
2010-04-18 11:24 crevette Новый вопрос
2010-04-19 00:07 skirsdeda Комментарий добавлен: 0001242


Mantis 1.1.6[^]
Copyright © 2000 - 2008 Mantis Group